Overview of Mine Fire Detection

By Edwards, John C.

Click here to view

Book Id: WPLBN0000092737
Format Type: PDF eBook
File Size: 0.9 MB
Reproduction Date: 2005
Full Text

Title: Overview of Mine Fire Detection  
Author: Edwards, John C.
Volume:
Language: English
Subject: Health., Medical research, Medical reports
Collections: Medical Library Collection
Historic
Publication Date:
Publisher: Centers for Disease Control and Prevention

Citation

APA MLA Chicago

Cwards, J. (Ed.). (n.d.). Overview of Mine Fire Detection. Retrieved from http://hawaiilibrary.net/


Excerpt
Several experimental programs were conducted at the Pittsburgh Research Center to investigate the level of mine fire detection and alarm capability possible using state-of-the-art technology. These programs involved comparison of the response and alarm time of optical and ionization type smoke sensors to smoldering and flaming coal combustion in a smoke chamber. Coal combustion experiments conducted in the smoke chamber demonstrated that a CO concentration of 5 ppm above ambient corresponded to an optical density of 0.022m. For the four smoke sensors for which a continuous analog signal was available, a smoke sensor alarm was defined as the average background signal plus ten times the peak-to-peak noise. This alarm criterion resulted in the association of the alarm for three of the four sensors with a smoke optical density of 0.011m and 0.033m for the fourth smoke sensor. The smoke sensors used in the smoke chamber studies were incorporated into large scale diesel fuel fire experiments conducted under normal ventilation conditions in the Safety Research Coal Mine (SRCM) at the Pittsburgh Research Center. These experiments showed that a diffusion mode smoke sensor alarmed earlier than a diffusion mode CO sensor; and, based upon the measurement of the optical transmission at the location of a pump mode ionization type smoke sensor. that a pump mode ionization smoke sensor alarmed at an average smoke optical density of 0.021m for the twelve experiments conducted. A series of 30 and 330 kW diesel fuel fire intensity experiments were conducted under zero airflow conditions in the SRCM. It was determined that: (I) thermal sensors are inadequate at 30 m from a 300 kW fire;(2) a diffusion mode ionization smoke sensor can be more effective for mine fire detection than a diffusion mode CO sensor;(3) recommendations can be made for sensor spacing in a mine entry based upon the measured CO buoyancy induced spread rates along the mine roof and the time for a developing coal fire to ignite a conveyor belt.

Table of Contents
Na

 

Click To View

Additional Books


  • Review of Multifrequency Channel Decompo... (by )
  • Object Extraction and Identification in ... (by )
  • World Health Organization Publication : ... (by )
  • World Health Organization Publication : ... (by )
  • Report on the Analysis of the Quality As... 
  • Corrosion Detection Technologies Sector ... (by )
  • Very Low Bit Rate Wavelet-Based Scalable... (by )
  • Intrusion Detection Systems (by )
  • Gmis : An Experimental System for Data M... (by )
  • Levels of Disease Diagnosis (by )
  • A Fault Detection Neural Network for Dc ... (by )
  • Real Time Computer Surveillance for Crim... (by )
Scroll Left
Scroll Right

 



Copyright © World Library Foundation. All rights reserved. eBooks from Hawaii eBook Library are sponsored by the World Library Foundation,
a 501c(4) Member's Support Non-Profit Organization, and is NOT affiliated with any governmental agency or department.